Choose a capture mode

Match the mode to the task before the first rep.

ModeUse it forCheck before capture
VerticalJump Height (JH), calculated from flight timeRep target, height units and the JH threshold.
ContactContact Time (CT)CT unit, CT Threshold and CT Cap. The cap applies only in Contact.
Reactive Strength Index (RSI)RSI from JH and CTStart position, rep target and thresholds.
Drop JumpDrop jump results, including the Dynamic Rebound Index (DRI)Measured drop height, score calculation, start position and side.
Plyomat Power Score (PPS)Jump energy from total mass and jump heightThe athlete’s body weight, any added weight, and their units.
Bounce Factor (BF)Repeated hop scoringThe required sequence and rep target for the task.
TimerCapture within a timed windowDuration and contact target. Use Start and the countdown.
FreeOpen capture of contacts and flightsContact target and the CT and Flight Time (FT) thresholds.

Auto Save is offered in every mode except Timer and Free. See Auto Save and Auto Progress.

Display versus a named assessment

Display lets you set each mode’s Controls. Assessments use a saved protocol with its own mode, side, target and kept selection rule. If Controls says Controls locked, change the protocol in Assessments rather than overriding it in Display.

Set the Controls

  1. Choose the capture mode and open Controls.
  2. Set the rep or contact target where offered. The control reads 0 = unlimited (auto-end disabled); at 0 you end each set yourself.
  3. Set Start position to On Mat or Off Mat where offered, matching how the athlete actually starts.
  4. For Drop Jump, enter the measured drop height. For PPS, confirm body weight and added weight. Check the units on each field.
  5. Turn on only the thresholds you intend to use, then close Controls.
ControlMeaning
Rep target or Contact targetThe planned count. Auto Save needs a rep target above 0. Timer and Free count contacts, and a contact count does not guarantee a full flight and contact pair.
JH ThresholdColor feedback for jump height. It is not a calibration.
CT ThresholdColor feedback for contact time. It does not change which contacts are accepted.
FT ThresholdFlight time feedback where offered. Check the unit shown.
Auto ResetClears the current unsaved capture for a fresh set. It is paused while Auto Save is on for the mode. Save a completed set before moving on.
Start positionOn Mat or Off Mat. You set this; the app does not detect it.
TagsLabels for the set. Use the same complete tag combination for results you want to compare.

CT Cap is not CT Threshold

Contact Controls with CT Cap set to 1500 milliseconds, its Default 500 ms button, and a separate CT Threshold
Contact Controls, captured in app 3.1.5 with no athlete data. Open the image for the full screen.
ControlChangesDoes not change
CT CapThe longest contact the app accepts as a rep in Contact, up to 1500 ms.Controller firmware limits, raw recorded durations, RSI acceptance or assessment rules.
CT ThresholdPerformance colors, when turned on.Which reps are accepted, or the CT Cap.
  1. Open Display and select Contact.
  2. Open Controls and find CT Cap.
  3. Use the number field or slider to choose a cap up to 1500 ms.
  4. Use Default to return to the cap shown on that button.
  5. Check the setting before the next contact. Changes apply to new contacts and do not recover discarded ones.

Make Display fit the station

  1. Open Display on a tablet or larger screen.
  2. Open Scale in the footer or its Settings control.
  3. Choose a lower percentage for more space, or a higher one for larger tiles and text.
  4. Use Reset to 100% to return to the standard size.
  5. Check that the controls, rep list and action buttons are all visible before athletes begin.
SettingScope
Scale, 50 to 120% in steps of 10Live Display on larger screens. Saved on this device and browser only.
Cloud pages and ReportsUse their own layouts; Scale does not resize them.
Small screensShown at 100%. Your saved Scale returns on a larger screen.
Plyomat TV and full screen leaderboardsNot affected by Scale.

Arrange the live view

Use Layout or Edit where offered to choose the live panels for the session. Keep the result and the rep list visible. A hidden panel does not mean its metric was not captured; check the saved set.

If the app opens with only part of the screen usable, save any set first, note the device and orientation, and reopen the app. Contact support with the device model and app version if it continues.

End, review and save

  1. Choose End set when the capture is complete. A rep target may end it for you.
  2. Review the results: athlete, mode, side and reps.
  3. Choose Save if the set is correct. Choose Discard only if you mean to lose the unsaved results.
  4. Open Sessions and confirm the set belongs to the right athlete.
  5. Only then move to the next athlete or close the app.
Action or messageWhat it means
End set or EndFreezes the results for review. It does not save.
SaveSaves the completed set for the selected athlete.
DiscardDrops the unsaved result and resets. There is no Undo.
Auto SaveSaves the set by itself at the rep target. Discard? on the receipt removes it for about six seconds. See Auto Save.
New →Starts again when no athlete save is available. It does not save.
Couldn’t save setKeep the page open and use Retry. Dismiss clears the failed set, so do not use it if you still need that set.

Wrong athlete or incorrect set?

Open the saved set in Sessions before correcting it. Permanent deletion, rep exclusion and whole set archive have different effects; see Review unusual readings.

Run a named assessment

  1. Open Assessments and choose the named test.
  2. Read its mode, side, rep target, kept selection and required inputs. Enter the athlete’s body weight or the drop height if the test needs it.
  3. Choose Run and confirm the active athlete.
  4. Follow the capture sequence on screen. Locked Controls mean the protocol sets them.
  5. Complete the required reps and review the kept results.
  6. Choose Save when the test is complete, or when a permitted partial test is ready. Check it in Sessions.

In a battery, complete or discard each protocol in turn.

With Auto Save and Auto Progress

With Auto Save on for assessments, a test that has a rep target saves itself when the target is met, and every rep is saved. Single-leg tests must reach the target on both sides. Assessments keep one Auto Save setting for all tests.

With Auto Progress on, the test never changes by itself. Each selected athlete does the current test once, then the screen asks you to choose the next test or to Run it again. See Auto Progress in assessments.

Single-leg tests

Follow the Left and Right prompts. Reset Left or Reset Right clears that side so you can repeat it, and the other side’s reps are kept. End set ends the whole assessment, including a partial side.

When an assessment requires its full rep count, early End set is hidden and both sides must reach the count before Save. If that requirement is off, ending early can produce a partial assessment, which is not equivalent to the completed protocol.

Assessment history

Open the test’s saved results, or its report in Reports. Check dates, source and kept selection. A deleted or archived protocol does not turn its saved sessions into Display sessions.